Description
The MGE-DMB1 Defibrillator is a cutting-edge medical device designed to provide life-saving defibrillation and advanced cardiac monitoring in hospital and emergency settings. With its intuitive interface, rapid response time, and versatile functionality, the MGE-DMB1 ensures reliability and ease of use for healthcare professionals in critical situations. This defibrillator is ideal for ICUs, emergency rooms, and ambulatory services.
Key Features
- Display:
- 8-inch high-resolution LCD for clear visualization.
- Displays HR, lead/pads status, alarms, SpO2, AED prompts, and delivered energy.
- Defibrillator Functions:
- Biphasic waveform for efficient energy delivery.
- Fast charge time: under 7 seconds with a fully charged battery.
- Energy selection: 2–360 joules with both manual and automatic modes.
- Voice and visual prompts for user guidance.
- Synchronization with R-wave for precise defibrillation in manual mode.
- ECG Monitoring:
- Supports 5-lead or 3-lead ECG cables and paddles.
- Leads: I, II, III, AVR, AVL, AVF, V; adjustable ECG size.
- Heart rate range: 20–300 BPM with configurable alarms.
- Smart Alarms and AED Mode:
- Detects and prompts for shockable rhythms like ventricular fibrillation and tachycardia.
- Auto-analyze and charge functionality with programmable energy levels.
- Recorder:
- 50 mm thermal printer with multiple speed settings.
- High-resolution printouts for clear event documentation.
- Manual or automatic print modes with a 9-second recording triggered by alarms.
- Battery:
- Rechargeable Ni-MH battery (12V) supporting up to 60 defibrillator discharges at maximum energy or 3 hours of continuous ECG monitoring.
Product Paramenter
| Item | Parameters |
|---|---|
| Origin | China |
| Product Name | Hospital Defibrillator |
| Model | MGE-DMB1 |
| MB Pacer (Optional) | |
| Type | VVI |
| Pulse Type | Rectangular, constant current |
| Pulse Amplitude | 0 to 180 mA ±10% or 5 mA (whichever is greater) |
| Pacing Rate | Variable from 30 ppm to 180 ppm ±1.5% (increments/decrements of 2 ppm) |
| Multi-Function Electrode (MFE) Pads | Multipurpose defibrillation/pacing electrodes |
| Pause | Pacing pulse frequency reduced by a factor of 4 when activated |
| Refractory Period | NC (VVI demand does not have this specification) |
| MB EtCO2 (Optional) | |
| Type of Sensor | By-pass |
| Technical Principle | Non-dispersive infrared gas analysis (NDIR) |
| Storage Condition | -40°C to 70°C, <90% RH, non-condensing |
| Operating Conditions | 5°C to 50°C, 10% to 90% RH, non-condensing |
| Ambient Pressure | 55-115 kPa |
| Power Supply | 5 V ±5% (max ripple 200 mVp-p) |
| TDP | Typical: 120 mA, Excursion Calibration: 280 mA |
| Range | 0-19.7% (0-150 mmHg, or 0-20 kPa) |
| Resolution | 0.1 mmHg |
| Accuracy | 0-40 mmHg: ±2 mmHg 41-70 mmHg: ±5% of reading 71-100 mmHg: ±8% of reading 101-150 mmHg: ±10% of reading |
| Respiratory Rate | 2-150 BPM |
| Respiratory Rate Accuracy | ±1% or ±1 BPM |
| MB NIBP (Optional) | |
| Measurement Unit | mmHg/kPa |
| Measurement Range | Adult: 10-270 mmHg Pediatric: 10-200 mmHg Neonatal: 10-135 mmHg |
| Resolution | 1 mmHg |
| Accuracy | Max mean error: ±5 mmHg Max standard deviation: ±8 mmHg |
| SpO2 Module (Optional) | |
| Measurement Range | 30-100% ±2% (80-90%) Others: ±5% |
| Alarm Range | User-defined high/low limits |
| Alarm Time Accuracy | Less than 12 seconds |
| Brand Name | MEDIGEINT, MEDIGE |
|---|---|
| Certificate | ISO-9001/13485/14001/45001, CE, FDA |
| Factory type | Over 20 years medical equipment manufacturer |
| Packing | Carton or wooden case |
| Port | ShangHai, NingBo, TianJin, QingDao, GuangZhou |
| Sample/Service Manual/OEM | Available |
| Warranty | 5 Years |